🚚 Free Worldwide Shipping on All Orders!Shop Now
Ready-to-Use Thermocouple: K type (Ni-Cr/Ni-Al) 118.5 mm (4.6") Length with Ceramic Sheath - TCK11
HomeStore

Ready-to-Use Thermocouple: K type (Ni-Cr/Ni-Al) 118.5 mm (4.6") Length with Ceramic Sheath - TCK11

Ready-to-Use Thermocouple: K type (Ni-Cr/Ni-Al) 118.5 mm (4.6") Length with Ceramic Sheath - TCK11

Features:

  • K-type thermocouple probe for measuring high heat applications at temperature up to 1250oC
  • Suitable for room temperature - 1200oC series furnaces, such as the KSL-1200X-J  
  • Ceramic end holder with screws to connect thermocouple to a temperature controller
  Specifications:
  • Length:                        118.5 mm (4.6")
  • Diameter of sheath:       8 mm, high purity Alumina 
  • Positive Material:           Nickel-Chromium
  • Negative Material:          Nickel-Aluminum
  • Wire diameter:               1.5 mm 
  • Lowest Temperature:     -200 oC
  • Highest Temperature:    1250  oC
  • Minimum Std. Error:      +/- 2.2  oC
 
  • A=77mm
  • B=41.5mm


Application Note:

  • If necessary, please check out K type thermocouple extension wire with male mini plug.
  • There are two polarities for K-type thermocouple: positive and negative. Please check the polarity of K type thermocouple before use. The wrong polarity may cause the temperature measuring error.
  • It is also easy to test the polarity of K type thermocouples. The negative wire is MORE magnetic than the positive wire. Just put a magnet up to each wire. One will be more magnetic than the other.



$38.15

Original: $109.00

-65%
Ready-to-Use Thermocouple: K type (Ni-Cr/Ni-Al) 118.5 mm (4.6") Length with Ceramic Sheath - TCK11

$109.00

$38.15

More Images

Ready-to-Use Thermocouple: K type (Ni-Cr/Ni-Al) 118.5 mm (4.6") Length with Ceramic Sheath - TCK11 - Image 2

Ready-to-Use Thermocouple: K type (Ni-Cr/Ni-Al) 118.5 mm (4.6") Length with Ceramic Sheath - TCK11

Features:

  • K-type thermocouple probe for measuring high heat applications at temperature up to 1250oC
  • Suitable for room temperature - 1200oC series furnaces, such as the KSL-1200X-J  
  • Ceramic end holder with screws to connect thermocouple to a temperature controller
  Specifications:
  • Length:                        118.5 mm (4.6")
  • Diameter of sheath:       8 mm, high purity Alumina 
  • Positive Material:           Nickel-Chromium
  • Negative Material:          Nickel-Aluminum
  • Wire diameter:               1.5 mm 
  • Lowest Temperature:     -200 oC
  • Highest Temperature:    1250  oC
  • Minimum Std. Error:      +/- 2.2  oC
 
  • A=77mm
  • B=41.5mm


Application Note:

  • If necessary, please check out K type thermocouple extension wire with male mini plug.
  • There are two polarities for K-type thermocouple: positive and negative. Please check the polarity of K type thermocouple before use. The wrong polarity may cause the temperature measuring error.
  • It is also easy to test the polarity of K type thermocouples. The negative wire is MORE magnetic than the positive wire. Just put a magnet up to each wire. One will be more magnetic than the other.



Product Information

Shipping & Returns

Description

Features:

  • K-type thermocouple probe for measuring high heat applications at temperature up to 1250oC
  • Suitable for room temperature - 1200oC series furnaces, such as the KSL-1200X-J  
  • Ceramic end holder with screws to connect thermocouple to a temperature controller
  Specifications:
  • Length:                        118.5 mm (4.6")
  • Diameter of sheath:       8 mm, high purity Alumina 
  • Positive Material:           Nickel-Chromium
  • Negative Material:          Nickel-Aluminum
  • Wire diameter:               1.5 mm 
  • Lowest Temperature:     -200 oC
  • Highest Temperature:    1250  oC
  • Minimum Std. Error:      +/- 2.2  oC
 
  • A=77mm
  • B=41.5mm


Application Note:

  • If necessary, please check out K type thermocouple extension wire with male mini plug.
  • There are two polarities for K-type thermocouple: positive and negative. Please check the polarity of K type thermocouple before use. The wrong polarity may cause the temperature measuring error.
  • It is also easy to test the polarity of K type thermocouples. The negative wire is MORE magnetic than the positive wire. Just put a magnet up to each wire. One will be more magnetic than the other.



You may also like

NEW
Thumbnail 1

Inert Gas Regulator, Two Stage Brass 0-100 psi Analytical Cylinder Regulator - CGA-580-LD

$1,090.00

NEW
Thumbnail 1

PPM Grade Dual Column Inert Gas Purifier with Regeneration Heater (Removing O2 & H2O to PPM) - GPH-DHDO

$2,998.00

-65%NEW
Thumbnail 1Thumbnail 2

Seamless Stainless Steel Tube: 1/4" OD x79"L (2000mm) for Gas Delivery (2 pcs/package) - SS14Tube

$130.00

$45.50

-65%NEW
Thumbnail 1

Fuse Holder for cylinder type fuse - FA-FH-4A-UL-LD

$19.00

$6.65

-65%NEW
Thumbnail 1

TE CONNECTIVITY CIRCUIT BREAKER, HYD-MAG, 2P, 277V, 40A -FA-F-40A-UL-LD

$61.95

$21.68

-65%NEW
Thumbnail 1Thumbnail 2

TC Contactor, AC3 32A/15KW - TC1D3210-LD

$96.00

$33.60

-65%NEW
Thumbnail 1

COOPER BUSSMANN - DCM-4 - FUSE, 4A, 600V, FAST ACTING - FA-F-4A-UL-LD

$39.00

$13.65

-65%NEW
Thumbnail 1

Fiberglass Tape Coated with Teflon PTFE - 10 Mil, 1" x 18 yds - MTI-TAPE-S11728-LD

$109.00

$38.15

-65%NEW
Thumbnail 1

UNION HAND VALVE FOR 12mmOD TUBING VENTING TYPE, MTI-KJ-VLV12

$18.00

$6.30

-65%NEW
Thumbnail 1Thumbnail 2

Brushless DC Pump for EQ-KJ5000 -KJ50-Pump

$295.00

$103.25

-65%NEW
Thumbnail 1

HN Female Connector .906 inch Hole Spacing for VTC-1RF and VTC-2RF, MTI-PE4183

$49.99

$17.50

-65%NEW
Thumbnail 1

High Pressure Solenoid Valve max 15 MPa, MTI-GSR-A52401004

$480.00

$168.00