Features:
  • Super Accurate, Super Stable, Super Value
  • For Use with Temperatures Up to 1335 oC (2440 o F)
  • Excellent Long Term Stability at High Temperature
  • Nickel-Chrome Based Superalloy Sheathing Provides Excellent High-Temperature Performance
  • Excellent Oxidation, Carburization, and Chlorination Resistance
  • Made with materials of Special Limits of Error. Perfect for calibrating MTI tube furnaces using a precision temperature calibrator (matched with a standard plug; related product below )
    Use with MTI'sĀ GSL-1100X Series, OTF-1200X Series, andĀ OTF-1200X-S.
Specifications:
  • Length: 8"
  • DiameterĀ of sheath: 3mm diameter
  • Positive Material: Ni-Cr
  • NegativeĀ Material: Ni-Al
  • Highest Temperature: 1200Ā oC
  • Lowest Temperature: 0 oC
Ā 
Application Note:
  • If necessary, please check outĀ K type thermocouple extension wire with mini male plug.Ā Using compensating wires is equivalent to stretching them to keep them operating at a constant temperature. The advantages of using compensating cables are saving material costs and solving the problem of constant temperature, etc.
  • There are 2 polarities for K-type thermocouples: positive and negative. Please check the polarity of K type thermocouple before use. The wrong polarity may cause the temperature measuring error.
  • It is also easy to test the polarity of K-type thermocouples. The negative wire is MORE magnetic than the positive wire. Just put a magnet up to each wire. One will be more magnetic than the other.
$148.99
Thermocouple: K type 3mm OD x 8" L with Alloy sheath and Standard Plug for Calibration - TCK8S3B-LD—
$148.99

Thermocouple: K type 3mm OD x 8" L with Alloy sheath and Standard Plug for Calibration - TCK8S3B-LD

Features:
  • Super Accurate, Super Stable, Super Value
  • For Use with Temperatures Up to 1335 oC (2440 o F)
  • Excellent Long Term Stability at High Temperature
  • Nickel-Chrome Based Superalloy Sheathing Provides Excellent High-Temperature Performance
  • Excellent Oxidation, Carburization, and Chlorination Resistance
  • Made with materials of Special Limits of Error. Perfect for calibrating MTI tube furnaces using a precision temperature calibrator (matched with a standard plug; related product below )
    Use with MTI'sĀ GSL-1100X Series, OTF-1200X Series, andĀ OTF-1200X-S.
Specifications:
  • Length: 8"
  • DiameterĀ of sheath: 3mm diameter
  • Positive Material: Ni-Cr
  • NegativeĀ Material: Ni-Al
  • Highest Temperature: 1200Ā oC
  • Lowest Temperature: 0 oC
Ā 
Application Note:
  • If necessary, please check outĀ K type thermocouple extension wire with mini male plug.Ā Using compensating wires is equivalent to stretching them to keep them operating at a constant temperature. The advantages of using compensating cables are saving material costs and solving the problem of constant temperature, etc.
  • There are 2 polarities for K-type thermocouples: positive and negative. Please check the polarity of K type thermocouple before use. The wrong polarity may cause the temperature measuring error.
  • It is also easy to test the polarity of K-type thermocouples. The negative wire is MORE magnetic than the positive wire. Just put a magnet up to each wire. One will be more magnetic than the other.

Product Information

Shipping & Returns

Description

Features:
  • Super Accurate, Super Stable, Super Value
  • For Use with Temperatures Up to 1335 oC (2440 o F)
  • Excellent Long Term Stability at High Temperature
  • Nickel-Chrome Based Superalloy Sheathing Provides Excellent High-Temperature Performance
  • Excellent Oxidation, Carburization, and Chlorination Resistance
  • Made with materials of Special Limits of Error. Perfect for calibrating MTI tube furnaces using a precision temperature calibrator (matched with a standard plug; related product below )
    Use with MTI'sĀ GSL-1100X Series, OTF-1200X Series, andĀ OTF-1200X-S.
Specifications:
  • Length: 8"
  • DiameterĀ of sheath: 3mm diameter
  • Positive Material: Ni-Cr
  • NegativeĀ Material: Ni-Al
  • Highest Temperature: 1200Ā oC
  • Lowest Temperature: 0 oC
Ā 
Application Note:
  • If necessary, please check outĀ K type thermocouple extension wire with mini male plug.Ā Using compensating wires is equivalent to stretching them to keep them operating at a constant temperature. The advantages of using compensating cables are saving material costs and solving the problem of constant temperature, etc.
  • There are 2 polarities for K-type thermocouples: positive and negative. Please check the polarity of K type thermocouple before use. The wrong polarity may cause the temperature measuring error.
  • It is also easy to test the polarity of K-type thermocouples. The negative wire is MORE magnetic than the positive wire. Just put a magnet up to each wire. One will be more magnetic than the other.