Thermocouple: K type 0.032" (0.8mm) OD x 6" L with Male Plug for Calibration - TCK6S1
Thermocouple: K type 0.032" (0.8mm) OD x 6" L with Male Plug for Calibration - TCK6S1
Ā
Features
Super Accurate, Super Stable, Super Value
For Use with Temperatures Up to 1200Ā oCĀ (2192Ā oĀ F)
Excellent Long Term Stability at High Temperature
Nickel-Chrome Based Super-alloy Sheathing Provides Excellent High Temperature Performance
Excellent Oxidation, Carburization and Chlorination Resistance
Made with materials of Special Limits of Error. Perfect for calibrating MTI tube furnaces using a precision temperature calibratorĀ
Length
Ā 6"
DiameterĀ of sheath
0.32" ( 0.81 mm )diameter
Dimension
Positive Material
Ni-Cr
NegativeĀ Material
Ni-Al
Highest Temperature
1200 oC
Lowest Temperature
-200Ā oC
Application Note
If necessary, please check outĀ K type thermocouple extension wire with mini male plug. Using compensating wires is equivalent to stretching them to keep them operating at a constant temperature. The advantages of using compensating cables are saving material costs and solving the problem of constant temperature, etc.
There are 2 polarities for K type thermocouple: positive and negative. Please check polarity of K type thermocouple before use. Wrong polarity may cause temperature measuring error.
It is also easy to test the polarity of K type thermocouples. The negative wire is MORE magnetic than the positive wire. Just put a magnet up to each wire. One will be more magnetic than the other.
Ā
$34.30
Original: $98.00
-65%
Thermocouple: K type 0.032" (0.8mm) OD x 6" L with Male Plug for Calibration - TCK6S1ā
$98.00
$34.30
Thermocouple: K type 0.032" (0.8mm) OD x 6" L with Male Plug for Calibration - TCK6S1
Ā
Features
Super Accurate, Super Stable, Super Value
For Use with Temperatures Up to 1200Ā oCĀ (2192Ā oĀ F)
Excellent Long Term Stability at High Temperature
Nickel-Chrome Based Super-alloy Sheathing Provides Excellent High Temperature Performance
Excellent Oxidation, Carburization and Chlorination Resistance
Made with materials of Special Limits of Error. Perfect for calibrating MTI tube furnaces using a precision temperature calibratorĀ
Length
Ā 6"
DiameterĀ of sheath
0.32" ( 0.81 mm )diameter
Dimension
Positive Material
Ni-Cr
NegativeĀ Material
Ni-Al
Highest Temperature
1200 oC
Lowest Temperature
-200Ā oC
Application Note
If necessary, please check outĀ K type thermocouple extension wire with mini male plug. Using compensating wires is equivalent to stretching them to keep them operating at a constant temperature. The advantages of using compensating cables are saving material costs and solving the problem of constant temperature, etc.
There are 2 polarities for K type thermocouple: positive and negative. Please check polarity of K type thermocouple before use. Wrong polarity may cause temperature measuring error.
It is also easy to test the polarity of K type thermocouples. The negative wire is MORE magnetic than the positive wire. Just put a magnet up to each wire. One will be more magnetic than the other.
Ā
Product Information
Shipping & Returns
Description
Ā
Features
Super Accurate, Super Stable, Super Value
For Use with Temperatures Up to 1200Ā oCĀ (2192Ā oĀ F)
Excellent Long Term Stability at High Temperature
Nickel-Chrome Based Super-alloy Sheathing Provides Excellent High Temperature Performance
Excellent Oxidation, Carburization and Chlorination Resistance
Made with materials of Special Limits of Error. Perfect for calibrating MTI tube furnaces using a precision temperature calibratorĀ
Length
Ā 6"
DiameterĀ of sheath
0.32" ( 0.81 mm )diameter
Dimension
Positive Material
Ni-Cr
NegativeĀ Material
Ni-Al
Highest Temperature
1200 oC
Lowest Temperature
-200Ā oC
Application Note
If necessary, please check outĀ K type thermocouple extension wire with mini male plug. Using compensating wires is equivalent to stretching them to keep them operating at a constant temperature. The advantages of using compensating cables are saving material costs and solving the problem of constant temperature, etc.
There are 2 polarities for K type thermocouple: positive and negative. Please check polarity of K type thermocouple before use. Wrong polarity may cause temperature measuring error.
It is also easy to test the polarity of K type thermocouples. The negative wire is MORE magnetic than the positive wire. Just put a magnet up to each wire. One will be more magnetic than the other.
Ā
You may also like
Inert Gas Regulator, Two Stage Brass 0-100 psi Analytical Cylinder Regulator - CGA-580-LD
$1,090.00
PPM Grade Dual Column Inert Gas Purifier with Regeneration Heater (Removing O2 & H2O to PPM) - GPH-DHDO
$2,998.00
Seamless Stainless Steel Tube: 1/4" OD x79"L (2000mm) for Gas Delivery (2 pcs/package) - SS14Tube
$130.00
-65%
Fuse Holder for cylinder type fuse - FA-FH-4A-UL-LD
$19.00
$6.65
TE CONNECTIVITY CIRCUIT BREAKER, HYD-MAG, 2P, 277V, 40A -FA-F-40A-UL-LD
$61.95
TC Contactor, AC3 32A/15KW - TC1D3210-LD
$96.00
COOPER BUSSMANN - DCM-4 - FUSE, 4A, 600V, FAST ACTING - FA-F-4A-UL-LD
$39.00
-65%
Fiberglass Tape Coated with Teflon PTFE - 10 Mil, 1" x 18 yds - MTI-TAPE-S11728-LD
$109.00
$38.15
UNION HAND VALVE FOR 12mmOD TUBING VENTING TYPE, MTI-KJ-VLV12
$18.00
Brushless DC Pump for EQ-KJ5000 -KJ50-Pump
$295.00
-65%
HN Female Connector .906 inch Hole Spacing for VTC-1RF and VTC-2RF, MTI-PE4183
$49.99
$17.50
High Pressure Solenoid Valve max 15 MPa, MTI-GSR-A52401004
$480.00
$34.30
Original: $98.00
-65%
Thermocouple: K type 0.032" (0.8mm) OD x 6" L with Male Plug for Calibration - TCK6S1ā